Specific migration and overall migration are both reported as results, but they answer different procurement questions. Overall migration is a screening figure for total transfer; specific migration is a targeted measurement of named substances against their own limits. Most disputes between a food factory and a film supplier start because one side assumed the other test had been run, and the paperwork never said which one it was.
Key Takeaways
- Overall migration screens total transfer; it cannot clear a named substance that carries its own limit.
- Specific migration depends on a substance list agreed before the test is booked.
- Read the two results in sequence, and treat a low overall figure beside a single high substance as the risk case.
- Both results lapse when the structure, ink system or adhesive chemistry changes.
How the two tests differ
| Dimension | Overall migration | Specific migration |
|---|---|---|
| What is measured | Total non-volatile mass transferred to the simulant | Mass of one named substance transferred |
| Unit convention | Mass per area of film in contact | Mass per kilogram of food, or per area |
| Typical use | Inertness screening, material change checks | Compliance against a substance limit |
| Requires a substance list | No | Yes, decided before testing |
| Detects a single bad actor | Poorly, it averages across all transfer | Directly |
| Detects an unknown risk | Sometimes, as an unexplained rise | Not at all |
The table shows why neither test replaces the other. Overall migration is cheap and broad; it catches a formulation change that pushes total transfer up. Specific migration is narrow and decisive; it catches the one substance that a regulator or a customer limit actually names.
Starting with overall migration
Order overall migration first when the structure is new to you and you have no substance list yet. It gives a baseline for how inert the film behaves in the intended simulant, and it is the fastest way to compare two candidate laminates on the same basis. It also works well in change control: if a converter switches adhesive supplier, a rise in overall migration is a signal worth investigating even before any named substance is tested.
Its weakness is resolution. A film that releases a small amount of one problematic substance and very little of everything else can still sit comfortably inside an overall limit. Use it as a filter, not as an approval document.
When specific migration becomes mandatory
Specific migration becomes mandatory as soon as a limit exists for a substance present in your structure. That covers common cases in flexible film: primary aromatic amines where certain ink or adhesive systems are used, epoxy derivatives from some laminating adhesives, caprolactam where polyamide appears in the structure, and additives whose limits are set individually. If the market you sell into names the substance, the test is not optional.
It also becomes the right tool when a customer audit asks a direct question. An auditor asking if a specific substance sits below its limit will not accept an overall figure as an answer, because the overall figure says nothing about that substance.
How do the two results combine?
Read them together, in that order, and expect one of four combinations. A low overall result with specific results under their limits is the clean case. A high overall result with all named substances compliant usually points to an unnamed migrant: an additive, an oligomer or a residue outside the list. That is the case worth chasing, because the limit you are measured against may not yet include the substance that is actually moving.
A low overall result with one specific substance above its limit is the most dangerous combination for a buyer, because the headline number looks reassuring. It is also the combination that appears most often when a report is summarised in a sales email rather than read in full.
The test a supplier usually sends
Suppliers most often provide overall migration, because it is generic and can be run without knowing the customer’s substance list. That is a reasonable default at quotation stage, but it is not sufficient for an approved supplier file. Ask the converter which specific substances their own structure carries, then request those results for the production material.
If the answer is that no specific test was ever run on the structure, treat the overall result as incomplete rather than as a pass. A short list of named substances with results is worth more than a long report with a single number.
Writing a usable test request
Write the request as three lines: structure and layer order, simulant and condition, and the substance list with the limit for each. Add the sample location and the batch reference. A request phrased as a bare request for a migration report will return whatever document the supplier has on file, which may be for a different structure entirely.
Where does this distinction apply?
It covers any food-contact film, including pouches, lidding film, sachets and roll stock, and to the food-contact face of laminated structures. It does not apply to non-food packaging such as detergent or lubricant pouches, where chemical resistance and transport performance are the governing questions. It also does not settle seal strength, barrier or shelf-life performance; those need their own tests.
The detection limit deserves one more word. A result reported as below detection counts only when the detection limit sits well under the regulatory threshold. Ask for that limit in writing on every report, because a detection limit above the threshold turns a clean-looking result into no information at all.
The related article on what a food factory should require from its film supplier sets out the document list, and the custom roll stock range shows the structures these tests normally cover. The regulatory basis for the substance categories referenced here sits in the United States food additive framework; 21 CFR Part 177 indirect food additives for polymers lists the polymer categories and their conditions of use, which is where a substance list usually begins.
Conclusion
Start with overall migration to establish a baseline and to compare candidates, then move to specific migration for every substance your market names. Keep both results in the supplier file and re-run them when the structure, ink system or adhesive changes. A buyer who asks for the specific test too early wastes money on a substance list that may change; a buyer who never asks for it holds a file that cannot answer an audit question. Neither test replaces the other, and the order of asking is the part most often skipped.
Frequently Asked Questions
Can specific migration be predicted from an overall migration result?
No, the two cannot be converted. Overall migration sums all transfer into one figure, while specific migration follows individual substances. A structure can sit well under the overall limit and still exceed the limit for one named substance, since that substance may be a small share of total transfer. The two must be ordered and read separately, and neither can be calculated from the other.
Does a higher overall migration number always mean a worse film?
No, and the comparison is fair only within the same simulant and condition. Different test conditions shift the figure, so a number from a fatty simulant cannot be set against one from an aqueous simulant. Compare like with like, and treat a rise within a consistent test setup as the signal worth investigating rather than as an absolute ranking of film quality. The overall figure also shifts with film thickness and with how much surface area the lab exposes, so the number is only meaningful next to the structure it came from. Keep the test parameters attached to the result whenever you forward a report internally.
Which substances belong on the list for a printed pouch?
Start from the structure, not from a generic template. Ask the converter to name the ink system, the adhesive chemistry and the sealant additives used, then match those to the substances your market regulates. Printing ink and laminating adhesive are the two most common sources, so those entries belong on the list before any test is scheduled. If your structure includes a foil layer or a polyamide layer, ask what those materials contribute as well.
How often should both tests be repeated?
Repeat when something in the structure or process changes: a new film, a new ink or adhesive supplier, a revised curing schedule, or a product reformulation that alters the fat or alcohol profile. Between changes, routine control belongs in incoming material checks and supplier certificates rather than in repeated full testing. Our guide to the certificate of analysis for packaging film covers what to check on each delivery.